logo
các sản phẩm
Chi tiết sản phẩm
Nhà > các sản phẩm >
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter

Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter

MOQ: 1PC
bao bì tiêu chuẩn: Carton
Thời gian giao hàng: 5-8 work days
phương thức thanh toán: L/C,D/A,D/P,T/T,Western Union,MoneyGram
khả năng cung cấp: 100PCS/Month
Thông tin chi tiết
Place of Origin
China
Hàng hiệu
XINYIYB
Model Number
XYTGFM-XXX
Product Name:
Thermal Gas Mass Flow Meter
Type:
Variable Area Air & Gas Flowmeters
Material:
Stainless Steel
Medium:
Gas
Pipe Diameter Range:
DN15-DN1000
Accuracy:
2.5%FS
Output:
4-20mA /RS485
Sensor Operating Temperature:
-40~300℃
Converter Operating Temperature:
-20~45℃
Working pressure:
≤2.5Mpa
Power Supply:
DC 24V
Power:
>18W
Mô tả sản phẩm
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter
The sensor part of the thermal gas mass flow meter consists of two reference level platinum anode temperature sensors. During instrument operation, one sensor continuously measures the medium temperature T1; Another sensor self heats to a temperature higher than the medium temperature T2, which is used to sense the fluid flow rate and is called a velocity sensor. The temperature AT=T2-T1, T2>T1. When there is fluid flowing through, the gas molecules collide with the sensor and take away the heat of T2, causing the temperature of T2 to decrease. To keep T constant, it is necessary to increase the power supply current of T2. The faster the gas flows, the more heat is taken away. There is a fixed functional relationship between the gas flow rate and the increased heat, which is the principle of constant temperature difference

Detail images
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 0
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 1
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 2
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 3
Specification
Performance
Technical Parameter

Structural Style
Plug-in Type
Pipeline Type
Pipe Diameter Range
DN15-DN4000
DN15-DN2000
Flow Rate Range
0.1-12Nm/s

Accuracy
±1~2.5%

Operation Temperature
Sensor: -40~220 ℃  Converter: -20~45 ℃

Working pressure
Medium pressure ≤ 2.5Mpa
Medium pressure ≤ 4Mpa
Power supply
DC 24V  AC220V ≤18W

Response Speed
1S

Output Signal
4-20mA   RS485

Alarm Signal
1-2 relay normally open contacts, 10A/220V/AC, 5A/30V/DC

Pipe Material
Carbon steel, stainless steel, plastic, etc






các sản phẩm
Chi tiết sản phẩm
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter
MOQ: 1PC
bao bì tiêu chuẩn: Carton
Thời gian giao hàng: 5-8 work days
phương thức thanh toán: L/C,D/A,D/P,T/T,Western Union,MoneyGram
khả năng cung cấp: 100PCS/Month
Thông tin chi tiết
Place of Origin
China
Hàng hiệu
XINYIYB
Model Number
XYTGFM-XXX
Product Name:
Thermal Gas Mass Flow Meter
Type:
Variable Area Air & Gas Flowmeters
Material:
Stainless Steel
Medium:
Gas
Pipe Diameter Range:
DN15-DN1000
Accuracy:
2.5%FS
Output:
4-20mA /RS485
Sensor Operating Temperature:
-40~300℃
Converter Operating Temperature:
-20~45℃
Working pressure:
≤2.5Mpa
Power Supply:
DC 24V
Power:
>18W
Minimum Order Quantity:
1PC
Packaging Details:
Carton
Delivery Time:
5-8 work days
Payment Terms:
L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability:
100PCS/Month
Mô tả sản phẩm
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter
The sensor part of the thermal gas mass flow meter consists of two reference level platinum anode temperature sensors. During instrument operation, one sensor continuously measures the medium temperature T1; Another sensor self heats to a temperature higher than the medium temperature T2, which is used to sense the fluid flow rate and is called a velocity sensor. The temperature AT=T2-T1, T2>T1. When there is fluid flowing through, the gas molecules collide with the sensor and take away the heat of T2, causing the temperature of T2 to decrease. To keep T constant, it is necessary to increase the power supply current of T2. The faster the gas flows, the more heat is taken away. There is a fixed functional relationship between the gas flow rate and the increased heat, which is the principle of constant temperature difference

Detail images
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 0
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 1
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 2
Thermal Gas Mass Flow Meter Insertion Type Natural Gas Oxygen Pipeline Type Micro Gas Flow Meter 3
Specification
Performance
Technical Parameter

Structural Style
Plug-in Type
Pipeline Type
Pipe Diameter Range
DN15-DN4000
DN15-DN2000
Flow Rate Range
0.1-12Nm/s

Accuracy
±1~2.5%

Operation Temperature
Sensor: -40~220 ℃  Converter: -20~45 ℃

Working pressure
Medium pressure ≤ 2.5Mpa
Medium pressure ≤ 4Mpa
Power supply
DC 24V  AC220V ≤18W

Response Speed
1S

Output Signal
4-20mA   RS485

Alarm Signal
1-2 relay normally open contacts, 10A/220V/AC, 5A/30V/DC

Pipe Material
Carbon steel, stainless steel, plastic, etc






Sơ đồ trang web |  Chính sách bảo mật | Trung Quốc Chất lượng tốt Máy phát áp suất chênh lệch Nhà cung cấp. 2025 Xi'an Xinyi Instrument Technology Co., Ltd. Tất cả các quyền được bảo lưu.